bg
(0)

Megger DCM305E GROUND LEAKAGE CLAMPMETER

The DCM305E is ideal for measuring the ground leakage current in a circuit where the RCD keeps tripping out unexpectedly. The measured result will quickly identify whether the earth leakage current present is excessive, causing the RCD to trip, or if the RCD itself is over sensitive or faulty. Additionally, this clampmeter vastly improves measurements […]

Readmore

Multi RLM-10+ Flexible Leakage/Line Current Tester

SPECIFICATIONS – CURRENT DETECTION PART Sensoring Method Flexible Split-Core Type Inside Diameter φ210mm (total length approx. 650mm) Influence of Residual Current Less than 0.25A (at AC 50A, the point where influence is most receivable) Withstanding Voltage AC 2200V/1 minute Length of Lead Wire Approx. 2m between CT and Measuring Part SPECIFICATIONS – MEASURING PART Measuring […]

Readmore

MULTI M-2010 Digital Clamp Tester (CE)

SPECIFICATIONS Withstanding Voltage AC 5500V 1 minute max. (Between the core of CT and outer case) Storage Temperature -10℃ to 60℃, 70%RH max. ( Without condensation ) Accuracy (23℃±5℃, 80%RH or less) Function/Range/Accuracy/Maximum input AC A (50/60Hz) Manual ranging/20A/±1.2% rdg ±10 dgt/AC600A AC A (50/60Hz) Manual ranging/200A/±1.2% rdg ±10dgt/AC600A AC A (50/60Hz) Manual ranging/600A/±1.0% rdg […]

Readmore

MULTI M-140 Mini AC Leakage Current Clamp Tester (CE)

SPECIFICATIONS Safety standard IEC 61010-1, IEC 61010-2-032 Installation CategoryⅡ600V or CategoryⅢ300V. E.M.C. standard EN 61326 Measuring method Dual slope integration mode Range AC 0~30mA/300mA, 30A/300A, 2 range manual Accuracy 23℃±5℃ 80%RH or less (50/60Hz) Range AC 30/300mA/0.01mA/±1.2% rdg ± 5dgt AC 30/300A/0.01A/0~200A : ±1.2% rdg ± 5dgt 200~250A : ±3.0% rdg ± 5dgt 250~300A : […]

Readmore

Fluke i2500-18 iFlex® Flexible Current Probes

The Fluke iFlex® flexible current probes expand the measurement range of the select Fluke meters to 2500 A AC while providing the ultimate measurement flexibility. The iFlex® probes connect directly to the meter, displaying current measurements without error prone scaling factors. The 1.8 m (6 ft) cord allows separation between the measurement location and the […]

Readmore

Kyoritsu 2431 Leakage Clamp Meters

AC A (50/60Hz) 20/200mA/200A ±3%rdg±5dgt (20/200mA/100A) ±5%rdg±5dgt (200A) AC A (WIDE) 20/200mA/200A ±2%rdg±4dgt [50/60Hz] (20/200mA/0 – 100A) ±5%rdg±6dgt [40 – 400Hz] (20/200mA/0 – 100A) ±5%rdg±4dgt [50/60Hz] (100.1 – 200A) Conductor size Ø24mm max. Frequency response 40 – 400Hz Effect of external stray magnetic field Ø15mm 100A 10mA AC max. Safety Standard IEC 61010-1 CAT III […]

Readmore

Hioki AC LEAKAGE CLAMP METER CM4001

Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. Use the CM4001 to easily clamp within crowded cables in order to reduce work time and improve safety. With guaranteed accuracy from 0.60 mA to 600.0 A, the CM4001 provides a one-stop solution for a variety of applications. A built-in […]

Readmore

Hioki AC CLAMP METER CM3289

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’ s expertise in current sensing technology. The CM3289 is a True RMS rectifying 1000A AC clamp meter that features a broad operating temperature range of -25° C to 65° C, thin and compact clamp core and optional flexible current sensor that you can attach to let […]

Readmore

Hioki AC CLAMP METER 3280-10F

Using 3280 series AC clamp meters: Introduction to functionality and measurement methods In addition to AC current measurement, these clamp meters provide voltage and resistance measurement as well as continuity check functionality. Their compact size, low-profile design, and resistance to both rough handling and extreme temperatures make them essential tools for any electrician.   Basic […]

Readmore

Extech MA443 400A True RMS AC Clamp Meter + NCV

Specifications Range (Max. Resolution) AC Current 400.0A (1mA) True RMS DC Current — Basic Current Accuracy AC: ±1.8% DC Voltage 600V (0.1mV) True RMS AC Voltage 600V (1mV) Basic Voltrage Accuracy AC: ±1.2% DC: ±0.8% Non-Contact Voltage (NCV) 100 to 600V Resistance 40MΩ (0.1Ω) Capacitance 40mF (0.01nF) Frequency 1MHz (0.01Hz) Temperature (Type K – meter […]

Readmore

Fluke 368 FC Leakage Current Clamp Meter

Specifications: Fluke 368 FC Leakage Current Clamp Meter Electrical Specifications Measurement function Alternating current AC ampere range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A mA / A: manual selection3 mA / 30 mA / 300 mA: automatic selection3 A / 30 A / 60 A: automatic selection Range / Resolution […]

Readmore

CENTER 26_18 Flexible AC Clamp Meter (18″ Coil)

  Measurement Ranges: 30A/300A/3000A AC Output Resolution (LCD Display): 0.01A/0.1A/1A 8.5mm coil diameter allows measurement in tight spaces (Double insulated) 18” flexible sensor fit around conductors up to 5.8”in diameter TRMS Reading

Readmore