bg
logo
  • +65 6292 5161
  • [email protected]
user
My Account
Sign In/ Register
Browse Menu
  • Our Brands
  • All Products
  • Mechanical
    • Alignment
    • Vibration
      • Vibration Tester
  • Electronic & Electrical
    • Electrical Test Equipment
      • Voltage Detector
      • Earth Loop Impedance Tester
      • Phase Rotation meter
      • Earth Testers
      • Multifunction Testers
      • Power Quality Analysers
      • Proving Units
      • Residual Circuit Device Tester (RCD)
      • Socket Testers & Adaptors
      • Accessories
    • Electronic Component Instruments
      • LCR Meters
    • Multimeters
      • Digital & Analogue Multimeters
      • Bench Multimeters
      • Multimeter Accessories
  • Voltage, Utilities, Rail
    • Insulation Test Equipment
    • Earthing & Short Circuit Systems
      • Earth Ground Clamps
      • Earth Ground Testers
    • High Voltage Detection
      • Voltage detectors
    • UPS & Battery Testing
      • Battery Analyser & Testers
  • Network, CCTV & Data Telecomm Testers
    • WiFi Tester
      • WiFi Solution
    • Copper
      • Cable Verifier Tester
      • Cable Certifier Tester
      • Cable Qualifier Tester
    • Fiber
      • Fiber Optic Cable Visual Fault Finder
      • Fiber Cable Tester
      • Fiber Cable Certifier
      • Fiber Optical Time Domain Reflectometer (OTDR)
    • CCTV
      • Security Tester
  • Process & Industrial
    • Process Calibrator
      • Multifunction Calibrators
      • Voltage, Current & Loop Calibrators
      • Temperature Calibrator
      • Hart Communicator
    • Intrinsically Safe/ Ex-Proof Testers
      • Camera
      • Mobile Phone
      • Multimeter, Thermometer, Lighting, Voltage Detector
    • Manometers & Pressure Meters
  • HVAC & Plumbing
    • Air, Air Flow & Pressure
      • Refrigerant Leak Detectors
  • Thermography & Thermometer
    • Thermal Cameras
      • Body Temperature Screening Thermal Cameras
      • Electrical & Building inspections Thermal Cameras
    • Thermometers
      • Digital/ Handheld Thermometers
      • Food/Catering Thermometers & Timers
      • Infrared Thermometers
      • Accessories
  • Environmental & Gas
    • Environmental Testers
      • Air Quality Testers (CO, CO2, Temperature, Humidity)
      • Anemometers & Airflow Meters& Accessories
      • Borescopes & Accessories
      • Heat Stress Testers
      • Hygrometers & Humidity Meters
      • Light/Lux Meters
      • Microwave Leakage Detectors & EMF Meters
      • Moisture Meters
      • Multifunction Environment Meters
      • pH Meters & Water Quality Testers
      • Laser Distance Meters
      • Thickness Gauge
      • Tachometer
      • Sound Meters
      • Stopwatch/Clock
    • Gas Detectors
      • Gas Leak Detectors/ Analysers
      • Portable & Personal Gas Monitors
  • Dataloggers
    • Temperature & Humidity
    • Pressure & Vibration
  • Hardware & Supplies
    • Hand Tools & Accessories
    • Power Tools & Accessories
    • Ladders & Work Platforms
    • Safety Equipment & PPE
    • Others
  • E-Store Exclusive Deal
  • Offer & Clearance
  • Mid Year Sale
-2
(0)
Home / Voltage, Utilities, Rail / Earthing & Short Circuit Systems / Earth Ground Testers / Fluke 1623-2 GEO Earth Ground Tester Kit
Sold Out
Zoom
*Click to enlarge,images are for illustrative purposes only.
Fluke

Fluke 1623-2 GEO Earth Ground Tester Kit

The Fluke 1623-2 GEO Earth Ground Tester offers data storage and download capabilities via USB port. World class accessories will simplify and speed up testing time.


0 in stock

Backorder available. Kindly email us to check on the lead time

Product price
Additional options total:
Order total:

$5,976.85

down
up
  • Product Description
  • Key Features
  • Technical Data

Fluke 1623-2 GEO Earth Ground Tester summary

-3- and 4-pole Fall-of-Potential, earth resistance loop testing
-4-pole Soil Resistivity testing
-Selective earth ground rod testing using 1 clamp
-Stakeless earth ground rod testing using 2 clamps
-IP56 rated for outdoor use
-Rugged carrying case
-USB data storage and transfer

 

Specifications: Fluke 1623-2 GEO Earth Ground Tester Kit

General Specifications
Display: 1999 digit LCD Display with special symbols, digit height 25 mm, fluorescent backlight
User interface Instant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button
Robust, water and dust resistant Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
Memory Internal memory storage up to 1500 records accessible via USB port
Temperature Range
Operating temperature -10°C to 50°C (14°F to 122°F)
Storage temperature -30°C to 60°C (-22°F to 140°F)
Temperature coefficient ±0.1% of reading/°C < 18°C > 28°C
Intrinsic error Refers to the reference temperature range and is guaranteed for 1 year
Operating error Refers to the operating temperature range and is guaranteed for 1 year
Climatic class C1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH
Protective type IP56 for case, IP40 for battery door according to EN60529
Safety Protection by double and/or reinforced insulation. max. 50 V to earth. IEC61010-1: Pollution degree 2
EMC (emission immunity) IEC61326-1: Portable
Quality system Developed, designed and manufactured according to DIN ISO 9001
External voltage V ext, max = 24 V (DC, AC < 400 Hz), measurement inhibited for higher values
V ext rejection > 120 dB (162⁄3, 50, 60, 400 Hz)
Measuring time Typical 6 seconds
Max. overload 250 V rms (pertains to misuse)
Auxiliary power 6 x 1.5 V Alkaline (type AA LR6)
Battery life span Typical > 3,000 measurements
Dimensions (W x H x D) 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)
Weight 1.1 kg (2.43 lb) including batteries
7.6 kg (16.8 lb) incl. accessories and batteries in carrying case
RA 3-Pole Ground Resistance Measurement (IEC 1557-5)
Switch position RA 3-pole
Resolution 0.001 Ω to 10 Ω
Measuring range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring voltage Vm = 48 V AC
Short-circuit current > 50 mA
Measure frequency 128 Hz
Probe resistance (RS) Max 100 kΩ
Auxiliary earth electrode resistance (RH) Max 100 kΩ
Additional error from RH and RS RH[kΩ]•••RS[kΩ]/RA[Ω]•••0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Ground Resistance Measurement (IEC 1557-5)
Switch position RA 4-pole
Resolution 0.001 Ω to 10 Ω
Measuring range 0.020 Ω to 19.99 kΩ
Accuracy ±(2% rdg + 3 d)
Operating error ±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring voltage Vm = 48 V AC
Short-circuit current > 50 mA
Measure frequency 128 Hz
Probe resistance (RS + RES) Max 100 kΩ
Auxiliary earth electrode resistance (RH) Max 100 kΩ
Additional error from RH and RS RH[kΩ]•••RS[kΩ]/RA[Ω]•••0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp )
Switch position RA 3-pole with clamp
Resolution 0.001 Ω to 10 Ω
Measuring range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring voltage Vm = 48 V AC
Short-circuit current > 50 mA
Measure frequency 128 Hz
Probe resistance (RS) Max 100 kΩ
Auxiliary earth electrode resistance (RH) Max 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp )
Switch position RA 4-pole with clamp
Resolution 0.001 Ω to 10 Ω
Measuring range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating error ±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring voltage Vm = 48 V AC
Short-circuit current > 50 mA
Measure frequency 128 Hz
Probe resistance (RS) Max 100 kΩ
Auxiliary earth electrode resistance (RH) Max 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
Stakeless Ground Loop Measurement (2 Clamps )
Switch position RA 4-pole 2 clamps
Resolution 0.001 Ω to 10 Ω
Measuring range 0.020 Ω to 19.99 kΩ
Accuracy ±(7% rdg + 3 d)
Operating error ±(10% rdg + 5 d)
Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers
Measuring voltage Vm = 48 V AC
Measure frequency 128 Hz
Noise current (IEXT) Max. IEXT = 10 A (AC) (RA < 20 Ω)
Max. IEXT = 2 A (AC) (RA > 20 Ω)
Automatic range selection.
The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.

takeless Testing

The Fluke 1623-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall-of-Potential test method must be used.

With Stakeless testing, the earth ground rod does not need to be disconnected – leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system – a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil.

The Most Complete Tester

The Fluke 1623-2 is a unique earth ground tester that can perform all four types of earth ground measurement.

  • 3- and 4-Pole Fall-of-Potential (using stakes)
  • 4-Pole Soil Resistivity Testing (using stakes)
  • Selective Testing (using 1 clamp and stakes)
  • Stakeless Testing (using 2 clamps only)

Datasheet [Fluke 1623-2_1625_2]

Share on social media:
product - call for price






    CE-Test & Measurement (S) Pte Ltd

    • 19 Kallang Avenue #02-159/161/163, Singapore 339410
    • 10 Jalan Besar #B1-18, Sim Lim Tower, Singapore 208787
    • +65 6292 5161
    • [email protected]
    • About Us
    • Brand
    • Promotions
    • Contact Us
    • My account
    • Blog
    • FAQ
    • Data Protection Notice
    • Payment And Delivery
    • Terms & Conditions
                       

    AFFILIATED WEBSITES

    Payment Methods
    Follow our social media
    @Copyright 2022 CE-Test & Measurement. All Right Reserved