bg
logo
  • +65 6292 5161
  • [email protected]
user
My Account
Sign In/ Register
Browse Menu
  • Our Brands
  • All Products
  • Electronic & Electrical
    • Electrical Test Equipment
      • Voltage Detector
      • Earth Loop Impedance Tester
      • Phase Rotation meter
      • Earth Testers
      • Multifunction Testers
      • Power Quality Analysers
      • Proving Units
      • Residual Circuit Device Tester (RCD)
      • Socket Testers & Adaptors
      • Accessories
    • Electronic Component Instruments
      • LCR Meters
    • Multimeters
      • Digital & Analogue Multimeters
      • Bench Multimeters
      • Multimeter Accessories
  • Voltage, Utilities, Rail
    • Insulation Test Equipment
    • Earthing & Short Circuit Systems
      • Earth Ground Clamps
      • Earth Ground Testers
    • High Voltage Detection
      • Voltage detectors
    • Vibration
      • Vibration Tester
    • UPS & Battery Testing
      • Battery Analyser & Testers
  • Network, CCTV & Data Telecomm Testers
    • WiFi Tester
      • WiFi Solution
    • Copper
      • Cable Verifier Tester
      • Cable Certifier Tester
      • Cable Qualifier Tester
    • Fiber
      • Fiber Optic Cable Visual Fault Finder
      • Fiber Cable Tester
      • Fiber Cable Certifier
      • Fiber Optical Time Domain Reflectometer (OTDR)
    • CCTV
      • Security Tester
  • Process & Industrial
    • Process Calibrator
      • Multifunction Calibrators
      • Voltage, Current & Loop Calibrators
      • Temperature Calibrator
      • Hart Communicator
    • Intrinsically Safe/ Ex-Proof Testers
      • Camera
      • Mobile Phone
      • Multimeter, Thermometer, Lighting, Voltage Detector
    • Manometers & Pressure Meters
  • HVAC & Plumbing
    • Air, Air Flow & Pressure
      • Refrigerant Leak Detectors
  • Thermography & Thermometer
    • Thermal Cameras
      • Body Temperature Screening Thermal Cameras
      • Electrical & Building inspections Thermal Cameras
    • Thermometers
      • Digital/ Handheld Thermometers
      • Food/Catering Thermometers & Timers
      • Infrared Thermometers
      • Accessories
  • Environmental & Gas
    • Environmental Testers
      • Air Quality Testers (CO, CO2, Temperature, Humidity)
      • Anemometers & Airflow Meters& Accessories
      • Borescopes & Accessories
      • Hygrometers & Humidity Meters
      • Light/Lux Meters
      • Microwave Leakage Detectors & EMF Meters
      • Moisture Meters
      • Multifunction Environment Meters
      • pH Meters & Water Quality Testers
      • Laser Distance Meters
      • Thickness Gauge
      • Tachometer
      • Sound Meters
      • Stopwatch/Clock
    • Gas Detectors
      • Gas Leak Detectors/ Analysers
      • Portable & Personal Gas Monitors
  • Dataloggers
    • Temperature & Humidity
    • Pressure & Vibration
  • Hardware & Supplies
    • Hand Tools & Accessories
    • Power Tools & Accessories
    • Ladders & Work Platforms
    • Safety Equipment & PPE
    • Others
  • E-Store Exclusive Promotion
  • Offer & Clearance
-2
(0)
Home / Electronic & Electrical / Clampmeter / AC & DC Clamp Meters / Fluke 376 FC True-RMS Clamp Meter
Zoom
*Click to enlarge,images are for illustrative purposes only.
Fluke

Fluke 376 FC True-RMS Clamp Meter

The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.

$825.37

1 in stock

Backorder available. Kindly email us to check on the lead time

Product price
Additional options total:
Order total:
down
up
  • Product Description
  • Key Features
  • Technical Data

Find the cause of difficult problems

The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.

Measure:

  • Voltage to 1000 V AC or DC
  • Resistance to 60 kΩ with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV DC measurement range to interface with other accessories
  • 1000 μF capacitance measurement

Work safely and conveniently

The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.

The included iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:

  • Expands the measurement range to 2500 A AC
  • Allows frequency measurement to 500 Hz with body jaw and iFlex

Specifications: Fluke 376 FC True-RMS Clamp Meter

General Specifications
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
i2500-10 Flex i2500-18 Flex
A
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)
Error ±0.5 % ±0.5 %
B
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)
Error ±1.0 % ±1.0 %
C
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)
Error ±2.0 % ±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ±5 digits
AC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits (20 Hz to 500 Hz)
DC Voltage
Range 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1% ±5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ±5 digits
Frequency via Jaw
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ±5 digits
Trigger level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ)
Accuracy 1% ±5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ±4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V
Batteries 2 AA, NEDA 15A, IEC LR6
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity –
non-condensing (< 10°C)
≤90% RH (at 10 °C to 30 °C)
≤75% RH (at 30 °C to 40 °C)
≤45% RH (at 40 °C to 50 °C)
Operating altitude 2000 m
Storage altitude 12,000 m
Size (L x W x H) 249 x 85 x 45 mm
Weight 395 g
Jaw opening 34 mm
Flexible current probe diameter 7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V
IP rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

 

  • Measures AC/DC current with included iFlex current probe
  • VFD low pass filter for accurate measurements of non-linear signals
  • Remotely log, trend and monitor to pinpoint intermittent faults
  • Inrush measurement to filter out noise and capture starting current

Datasheet [Fluke 370 FC Series]

Share on social media:
product - call for price






    CE-Test & Measurement (S) Pte Ltd

    • 19 Kallang Avenue #02-159/161/163, Singapore 339410
    • 10 Jalan Besar #B1-18, Sim Lim Tower, Singapore 208787
    • +65 6292 5161
    • [email protected]
    • About Us
    • Brand
    • Promotions
    • Contact Us
    • My account
    • FAQ
    • Data Protection Notice
    • Payment And Delivery
    • Terms & Conditions
                       

    AFFILIATED WEBSITES

    Payment Methods
    Follow our social media
    @Copyright 2022 CE-Test & Measurement. All Right Reserved