Manage and monitor workflow for better maintenance results
Using the Fluke Connect Mobile App it’s now easier than ever to manage your vibration screening workflow. Integrated machine profile functionality allows you to setup machine profiles using the app and then push them directly to your 805 FC Vibration Meter. Users can then use the list of machine profiles to create work orders, and develop route based maintenance schedules which can be dynamically sent to technicians in field, helping to ensure the proper focus on critical assets. Once a machine is tested, the 805 FC communicates the results directly to the app and associates them with the proper profile and route. This data can easily be shared between teams, so you can make better maintenance decisions.
Other useful features:
- Reliable, repeatable, accurate device for checking bearings and overall vibration
- Features innovative sensor design that minimizes measurement variations caused by device angle or contact pressure
- Provides consistent data quality at both low and high frequency ranges
- Offers four-level severity scale to assess urgency of problems and bearing condition
- Allows you to export data via USB or wirelessly, through the Fluke Connect® mobile app
- Compatible with Fluke Connect® Mobile App that can transmit measurements to your smartphone to be shared in real time
- Enables you to get authorization to take next steps in an instant if machine health is at risk via Fluke Connect™ mobile app*
- Allows you to view trending in Microsoft® Excel using pre-built templates
- Measures overall vibration (10 Hz to 1,000 Hz) for acceleration, velocity, and displacement units of measurement for a wide variety of machines
- Provides Crest Factor+ technology for reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
- Compares vibration levels with ISO-10816 severity scales and stores results to the Fluke Connect Cloud
- Features colored lighting system (green, red) and on-screen comments to indicate how much pressure needs to be applied to take measurements
- Measures temperature with Spot IR Sensor to increase diagnostic capabilities
- Holds and saves up to 3,500 measurements in on-board memory
- External accelerometer (optional) support for hard to reach locations
- Features built-in flashlight for viewing measurement locations in dark areas
- Provides large high-resolution display for easy navigation and viewing
Specifications: Fluke 805 FC Vibration Meter
Specifications | |
Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz |
Severity levels | Good, satisfactory, unsatisfactory, unacceptable |
Vibration limit | 50 g peak (100 g peak-peak) |
A/D converter | 16-bit |
Signal to noise ratio | 80 dB |
Sampling rate | Low frequency: 20,000 Hz High frequency: 80,000 Hz |
Real time clock backup | Coin battery |
Sensor | |
Sensitivity | 100 mV g ± 10% |
Measurement range | 0.01 g to 50 g |
Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
High frequency range | 4,000 Hz to 20,000 Hz |
Resolution | 0.01 g |
Accuracy | At 100 Hz ± 5% of measured value |
Amplitude Units | |
Acceleration | g, m/sec² |
Velocity | in/sec, mm/sec |
Displacement | mils, mm |
Infrared Thermometer (Temperature Measurement) | |
Range | -20 °C to 200 °C (-4 °F to 392 °F) |
Accuracy | ±2 °C (4 °F) |
Focal length | Fixed, at ~3.8 cm (1.5″) |
External Sensor | |
Note: Fluke supports but does not provide external sensors | |
Frequency range | 10 Hz to 1,000 Hz |
Bias voltage (to supply power) | 20 V dc to 22 V dc |
Bias current (to supply power) | Maximum 5 mA |
Firmware | |
External interfaces | USB 2.0 (full speed) communication |
Data capacity | Database on internal flash memory |
Upgrade | Through USB |
Memory | Up to 3,500 measurements |
Radiated Emission | |
Electrostatic discharge: burst | Standard EN 61000-4-2 |
Electromagnetic interference | Standard EN 61000-4-3 |
RE | Standard CISPR 11, Class A |
Environmental | |
Operating temperature | -20 °C to 50 °C (-4 °F to 122 °F) |
Storage temperature | -30 °C to 80 °C (-22 °F to 176 °F) |
Operating humidity | 10% to 95% RH (non-condensing) |
Operating/storage altitude | Sea level to 3,048 meters (10,000 feet) |
IP rating | IP54 |
Vibration limit | 500g peak |
Drop test | 1 meter |
General Specifications | |
Battery type | AA (2) Lithium Iron Disulfide |
Battery life | 250 measurements |
Size (L x W x H) | 24.1 cm x 7.1 cm x 5.8 cm (9.5 in x 2.8 in x 2.3 in) |
Weight | 0.40 kg (0.89 lb) |
Connectors | USB mini-B 7-pin, external sensor jack (SMB connector) |